"BANDELIN" SONOREX DIGITAL 10 P, Digital Ultrasonic Cleaners with 10-program Data memory. for Precise & Reproducible work, with Heater, 3~28Lit., 20 to 80 ¡ÆC ¡¾ 1.5 ¡ÆC., ÇÁ·Î±×·¥½Ä µðÁöÅÐÃÊÀ½Æļ¼Ã´±â
¡á ¿ëµµ(Applications) * The SONOREX DIGITAL range - with volumes from 3.0 to 28.0 litres. * Working with SONOREX DIGITAL 10 P is more comfortable and precise through user-friendly high-power ultrasound, integrated in digital ultrasound baths. * You select: time, temperature, power and DEGAS and store up to 10 variations. * Exact setting of all parameters guarantees reproducible results. * When switching off the unit, the data is stored automatically. * Å»°¡½ºÈ, ÈÇйÝÀÀÀÇ °¡¼ÓÈ, Plazma¿Í SeraÈ¥ÇÕ, ¿¡¸ÖÁ¯È, ½Ã·áÀÇ ±ÕÁúÈ, °¢Á¾ ºÐ¼®¿ë ½Ã·á Áغñ½Ã
¡á Á¦Ç°Æ¯Â¡(Features) * PZT-large area oscillating systems * HF-Frequency 35 kHz * Time setting between 1 to 99 min and continuous operation. Interruption is possible at any time. * Display of the remaining time. * Built-in heating, thermostatically adjustable between 20 to 80 ¡ÆC (68 to 176 ¡ÆF) * Integrated thermometer, accuracy ¡¾ 1.5 ¡ÆC. * Power setting from 10 to 100 %, microprocessor control * Oscillating tank of stainless steel * Housing of stainless steel - drip proof * Foil keypad * Drain cock for easy emptying (from DK 156 BP upward) * Mains connection 230 V~, 50/60 Hz * SONOREX DIGITAL units are RFI-proof and CE marked.
* PZT-DML-disc in a large area oscillating system ; produce the highest ultrasonic intensity * With 10-programme data memory * Easy-care and drip-proof stainless steel housing * For various applications ; Degassing of liquids, Accelerating chemical reactions, Mixing plasma and sera, Emulsifying, Homogenizing of samples, and Preparation of samples for analysis. * SONOREX DIGITAL 10P is more comfortable and precise due to exact setting of all parameters which are adhered to during the entire process. * All results are reproducible. Data are stored automatically when the unit is switched off. * 10°³ÀÇ ÇÁ·Î±×·¥ ¸Þ¸ð¸®,µðÁöÅÐ, 35kHzÀÇ À¯ÀÏÇÑ Á¦Ç°(°·ÂÇÑ È¿°ú) * ¾Æ·¡ÀÇ Parameters°¡ Á¤È®È÷ ¼³Á¤µÇ¹Ç·Î °³¿¬¼ºÀÖ´Â °á°ú¸¦ ¾òÀ» ¼ö ÀÖ´Ù. ¤ýÀÛ¾÷½Ã°£ : 1~99 min + ¿¬¼ÓÀÛµ¿ ¤ý¿Âµµ¼³Á¤ : 20~80¡É, Accuracy ¡¾1.5¡É, Display real bath temp. & selected temp. ¤ýÃÊÀ½ÆÄ ¼¼±â : 10~100%, Microprocessor control. ¤ýDegas : rapid degassing of liquids. * Switch off½Ã ÀÚµ¿ÀûÀ¸·Î ÀÛ¾÷³»¿ë ÀúÀå. * PZT-DML-transducers´Â Oscillating tank Àüü¿¡ °ÉÃÄ ÃÖ°ÀÇ ÃÊÀ½ÆÄ »ý¼º. * ¾ÈÀüÇÑ Drip-proof stainless steel housing. * RFI-proofed and CE-marked, 220V/60Hz. * Basket, LidµîÀÇ Accessories´Â º°µµ(Option)ÀÓ.
* Voltage : 220 V / 60 Hz. * Type BA.780 : DK102P BA.781 : DK156BP BA.782 : DK255P BA.784 : DK514BP BA.786 : DK1028P * Contents Lit. BA.780 : 3.0 BA.781 : 7.5 BA.782 : 5.4 BA.784 : 17.0 BA.786 : 26.0 * Interior tank dimension(L x w x d) mm BA.780 : 240 x 140 x 100 BA.781 : 500 x 135 x 150 BA.782 : 300 x 150 x 150 BA.784 : 325 x 300 x 200 BA.786 : 500 x 300 x 200 * Drain Cock BA.781 : 1/4" BA.782 : 1/4" BA.784 : 1/2" BA.786 : 1/2" * Peak output max.W/Per BA.780 : 2 x 240 BA.781 : 2 x 300 BA.782 : 2 x 320 BA.784 : 2 x 450 BA.786 : 2 x 600 * Heating capacity W BA.780 : 140 BA.781 : 600 BA.782 : 280 BA.784 : 600 BA.786 : 1300 * Connected load A BA.780 : 1.1 BA.781 : 3.3 BA.782 : 1.9 BA.784 : 3.6 BA.786 : 7.0
Overview on 3 ultrasonic baths
Features
DIGITEC
SUPER
DIGITAL 10 P
LONGLIFE
Tank volume (litres)
0.9 ~90.0
0.9 ~58.0
3.0 ~28.0
1.9 ~90.0
Control elements
push-buttons
turning knobs
push-buttons
turning knobs
Time setting (min)
1~30, continuous operation¡Ä
1~5, continuous operation¡Ä
1~9, continuous operation ¡Ä
1~5, continuous operation¡Ä
Safety shut-down
after 12 hours
no
no
no
Heating
optional, version "H"
optional, H-Version
yes
yes
Heating, thermostatically adjustable
20 ~80 ¡ÆC
30 ~80 ¡ÆC RK 31 H: 65 ¡ÆC fi xed
20 ~80 ¡ÆC
30 ~80 ¡ÆC
Excess temperature signal
yes
no
no
no
Protection against delay in boiling
yes, optionally switch-on
no
no
no
Setting accuracy of bath temperature
¡¾ 3.5 K
¡¾ 5 K
¡¾ 1.5 K
¡¾ 5 K
Thickness of stainless steel
0.8 mm. AISI 314
0.8 mm. AISI 304
0.8 mm. AISI 304
-
tank material
version "C"
2 mm. AISI 316 Ti
2 mm. AISI 316 Ti
-
2 mm. AISI 316 Ti
Marking of filling level for safe dosage
yes
yes
yes
yes
Hard chromium-plated
DT 102 H
RK 102 H
no
no
normal,
normal,
Lifetime
extended: version "C"
extended:
normal
extended
hard chromium-plated
hard chromium-plated
Warranty period (years)
2, DT 102 H = 3
2, RK 102 H = 3
2
3
One-piece drain, welded
yes, from DT 100 SH
yes, from RK 100 SH
yes, from DK 156 BP
yes, from RK 102 CH
Liquid protection
protected against spray
drip-proof
drip-proof
drip-proof
Degree of protection
IP 33
IP 32
IP 32
IP 32
Ultrasonic frequency (kHz)
35
35
35
35
Sweep
yes
yes
no
yes
Power adjustment
no
no
yes
no
PCT-transducers (PCT = lead circonate titanate)
yes
yes
yes
yes
Fast degassing
yes
no
yes
no
Mains supply 230 V~, 50/60 Hz
yes
yes
yes
yes
alternatively: mains supply 115 V~, 50/60 Hz
yes
yes
no
yes
Data memory
1 program (type H-RC)
no
10 programs
no
Interface
RS 232, type H-RC
no
no
no
PC software
yes
no
no
no
CE marked as medical device
yes, except for DT 1050 / CH
yes, except for RK 1050
no
yes, except for RK 1050 CH
For units with larger volumes (SONOREX TECHNIK) see last page.
SONOCOOL 255 Code No. 3500 *Consisting of: *Ultrasonic device, sample holder PH 255, for 8 inset beakers, *lid D 255 G, 10 inset beakers SD 01 à 100 ml, TICKOPUR TR 3 *(concentrate for producing the contact liquid) - 250 ml Vorteile * compact design * increased life span by welded tank: stainless steel AISI 316Ti, 2 mm thick * lid made of glass for easy cleaning and sample observation * level sensor for contact liquid as dry run protection * lighted LCD display for remaining time – actual temperature – pause/diagnostics – set time/set temperature – ultrasonic power * serial interface for remote control * Inset beaker SD 01100 ml, with ring(package à 10 pieces) Code No. 3516 Accessories * Sample holder PH 255 for 8 inset beakers SD 01 Code No. 3511 Decalcifi cation of bone tissue in pathology Decalcifying of bone tissue is an important step of histological preparation of samples (e.g. in oncology). Only decalcifi ed samples can be used artefact-free for followed diagnosis. Compared to standard methods, the processing time is extremely shortened. - no destroying of the morphologic structure of samples - quantity of aggressive decalcifying liquids is reduced - faster results of diagnosis Use in analysys laboratories With SONOCOOL¢ç the cathalytic effect of ultrasound can also be used when sonicating temperature-sensitive samples. Exotherm reactions are possible because of the integrated cooling system, processes are faster and more effective. SC 255 Technical data * Inner tank dimensions: 280 ¡¿ 150 ¡¿ 150 mm (l ¡¿ w ¡¿ d) * Tank volume: 5 litres (contact liquid) * Adjustable bath temperature: 15 – 30 ¡ÆC (at 20 ¡ÆC room temperature) * Cooling power: 200 W * Ultrasonic power: 180 W, adjustable in 4 steps * Ultrasonic frequency: 35 kHz, SweepTec¢ç * Countdown operation: up to 100 h * External dimensions: 360 ¡¿ 605 ¡¿ 385 mm (l ¡¿ w ¡¿ d) * Housing: aluminium: coated with fl ush pulls (grips recessed inside the housing) * Outlet: front left, concealed * Current consumption: 1.6 A * Mains connection: 230 V~, 50/60 Hz * Weight: 27.5 kg