·Î±×ÀÎ ¤Ó ȸ¿ø°¡ÀÔ ¤Ó Àå¹Ù±¸´Ï ¤Ó ÁÖ¹®/¹è¼ÛÁ¶È¸ ¤Ó ã¾Æ¿À½Ã´Â±æ ¤Ó Agency Shop
¼¼ÀÏ»óÇ° |  Á¦Ç°¼Ò°³ |  ¿Â¶óÀΰßÀû¼­ |  i-Shop |  °ü·Ã»çÀÌÆ® |  Manual |  ±â¼úÁ¤º¸ |  °í°´¼¾ÅÍ |  ¹°¹°±³È¯
Keyword or Catalog No (»óÇ°¸í.¸ðµ¨¸í.Á¦Á¶»ç¸í)    
¾ÆÀ̵ð
ºñ¹Ð¹øÈ£
¾ÆÀ̵ð ÀúÀå
¤¡. °ü·Ã»óÇ°º¸±â ¨¿
¤¤. °ü·Ã»óÇ°º¸±â ¨À
¤§. °ü·Ã»óÇ°º¸±â ¨Á
¤©. °ü·Ã»óÇ°º¸±â ¨Â
¤±. °ü·Ã»óÇ°º¸±â ¨Ã
¤². °ü·Ã»óÇ°º¸±â ¨Ä
¤µ. °ü·Ã»óÇ°º¸±â ¨Å
¤·. °ü·Ã»óÇ°º¸±â ¨Æ
¤¸. °ü·Ã»óÇ°º¸±â ¨Ç
¤º. °ü·Ã»óÇ°º¸±â ¨È
¤». °ü·Ã»óÇ°º¸±â ¨É
¤¼. °ü·Ã»óÇ°º¸±â ¨Ê
¤½. °ü·Ã»óÇ°º¸±â ¨Ë
¤¾. °ü·Ã»óÇ°º¸±â ¨Ì
* °úÇб³Àç (ÃÊ.Áß.°í)
* ±ÝÇü¼³°è.»çÃ⼺Çü
* ÁÖ¹®Á¦ÀÛÇ° (À¯¸®.Å×ÇÁ·Ð.±Ý¼Ó)
* ½Ã¾à. Àç·á.ÇÕ±Ý.Ÿ°Ù.¿þÀÌÆÛ
·¹µåºí·° Å×½ºÆ®¿ë  
±â¾÷ÀºÇà 086-023289-04-011
¿ì¸®ÀºÇà 048-401225-13-001
¿¹±ÝÁÖ : ±è¹Î¿Á
Alphabet Index
A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z

" HANNA" Model: HI 98230 & HI 98240 Printing and Logging pH Meters with GLP and Smart Electrode
Á¤»ó°¡ : 0¿ø
ÆǸŰ¡ :  VAT Æ÷ÇÔ°¡
Àû¸³±Ý : 0¿ø
Á¦Á¶»ç/¿ø»êÁö : HANNA/Italy
¹è¼Ûºñ : ÀϹÝ(°áÁ¦ÃѾ׿¡ µû¶ó¼­ º¯µ¿)
ÁÖ¹®¼ö·® :
°³

¡á Á¦Ç°ÄÚµå(CAT No) / °¡°ÝÇ¥(Price)
»óÇ°ÄÚµå Description ´ÜÀ§/°¹¼ö ÆǸŰ¡ VAT ÁÖ¹®Çϱâ
HI 98230pH -4.00~19.99, -10.0 ~120¡ÆCea/1650,000¿ø65,000¿ø
HI 98240pH -4.00~19.99, -10.0~120¡ÆC, ISE & ORP -400~400mvea/1695,000¿ø69,500¿ø


¡Ø Note! Ç¥½Ã°¡°ÝÀº ȯÀ² ¹× ¿øÀÚÀç º¯È­·Î º¯µ¿µÉ ¼ö ÀÖÀ¸¸ç ±ÇÀå ¼ÒºñÀÚ °¡°ÝÀÓ ( VAT º°µµ)¢Î 02)967-5978
±Ô°Ý¿Ü ÁÖ¹®Á¦ÀÛ ¹× °¡°Ý ³»°í °¡ ÇÊ¿ä·Î ÇϽŠºÐÀº º°µµ·Î °ßÀû¿äû or ÀüÈ­¹®ÀÇ ¹Ù¶ø´Ï´Ù.
FAX:02)967-5979
¡ØÀÎÅÍ³Ý ÁÖ¹®ÀÌ ÇÊ¿äÇϽŠºÐÀº ÀüÈ­Áֽøé ÇöÀç°¡°Ý µî·Ï ¼öÁ¤ ÈÄ ¿Â¶óÀÎ ÁÖ¹® °¡´ÉÇÕ´Ï´Ù

¡á
¿ëµµ(Applications)
*ÇöÀå¿¡¼­ µ¥ÀÌÅ͸¦ ±â·ÏÇÒ¼ö ÀÖ´Â ÇÁ¸°ÅÍ ÀåÂø
*-4¡­19.00pHÀÇ ³ÐÀº ÃøÁ¤¹üÀ§
*¾×Á¤ÀÌ ³Ð¾î¼­ pH/ORP¿Í ¿Âµ¶°¡ µÎÁÙ·Î µ¿½Ã¿¡ Ç¥½Ã
* HI 98230 and HI 98240 top-of-the-range pH meters offer many sophisticated features engineered into a highly portable meter; with the added advantage of a built-in plain paper printer, logging and log-on-demand.
* Featuring GLP (Good Laboratory Practice) capabilities, these instruments incorporate the
HANNA¢ç' intelligent electrode technology.
* All these features make HI 98230 and HI 98240 ideal for on-site as well as field laboratories.
* HI 98230 and HI 98240 are the perfect solution for any application where pH measurements need to be recorded.
* In fact, data can be stored or printed directly on demand or automatically.
* The stored data (up to 100 measurements on-demand and up to 1500 automatically) can be downloaded to a PC with a standard RS232 serial connection using
HANNA¢ç infrared adapter and HI 92000 Windows¢ç compatible software (not included), which permits the transfer of data to other programs.

¡áƯ ¡ (Features )
*
ÇÁ¸°ÅÍ ÀÎÅ͹úÀ» »ç¿ëÀÚ°¡ 1¡­180ºÐ±îÁö ÀÓÀ¸·Î ¼±ÅÃÇÒ¼ö ÀÖ´Ù.
* ÃøÁ¤Çß´ø µ¥ÀÌÅ͸¦ ³ªÁß¿¡ ÇÁ¸°Æ® ÇÒ¼ö ÀÖ´Ù.
* 1600°³ÀÇ ÃøÁ¤ µ¥ÀÌÅͱîÁö ÀúÀåÀÌ °¡´ÉÇÏ¸ç ¼ÒÇÁÆ®¿þ¾î¿Í RS232¿¬°áÀ» ÀÌ¿ëÇؼ­ ÄÄÇ»ÅÍ·Î µ¥ÀÌÅ͸¦ ´Ù¿î¹ÞÀ»¼ö ÀÖ´Ù.

¡á ±Ô°Ý(Specifications)
HI 98230
Range pH -4.00 to 19.99 pH
Range Temperature 10.0 to 120.0¡ÆC / -14.0 to 248.0¡ÆF
Resolution pH 0.01 pH
Resolution Temperature 0.1¡ÆC / 0.1¡ÆF
Accuracy pH ¡¾0.01 pH
Accuracy Temperature ¡¾0.5¡ÆC (0 to 70¡ÆC); ¡¾1¡ÆC (outside);
¡¾1¡ÆF (32 to 158¡ÆF); ¡¾1.8¡ÆF (outside)
pH Calibration   automatic, 1 or 2 point with 5 memorized buffer values
(pH 4.01, 6.86, 7.01, 9.18, 10.01)
Temperature Compensation   automatic, -10 to 120¡ÆC (14 to 248¡ÆF)
pH Electrode   HI 1618D smart electrode with temperature sensor,
DIN connector and 1 m (3.3') cable (included)
PC Connection   HI 9200/9 IR interface,
connector the computer RS232 serial port
Logging Interval   selectable at 1, 2, 5, 10, 15 30, 60, 120 or 180 minutes
Printing Interval   selectable at 1, 2, 5, 10, 15 30, 60, 120 or 180 minutes
Power Supply   4 x 1.5V AA / approx. 350 hours of continuous use (with backlight OFF)
or 12 Vdc input
Environment   0 to 50¡ÆC (32 to 122¡ÆF); RH max 95%
Dimensions   220 x 87 x 75 mm (8.7 x 3.4 x 2.9")
Weight   550 g (1.2 lb.)

HI 98240
Range pH -4.00 to 19.99 pH
Range mV ¡¾400.0 mV; ¡¾2000 mV
Range Temperature 10.0 to 120.0¡ÆC / -14.0 to 248.0¡ÆF
Resolution pH 0.01 pH
Resolution mV 0.1 mV (¡¾400 mV); 1 mV (outside)
Resolution Temperature 0.1¡ÆC / 0.1¡ÆF
Accuracy pH ¡¾0.01 pH
Accuracy mV ¡¾0.5 mV (¡¾400 mV); ¡¾2 mV (outside)
Accuracy Temperature ¡¾0.5¡ÆC (0 to 70¡ÆC); ¡¾1¡ÆC (outside);
¡¾1¡ÆF (32 to 158¡ÆF); ¡¾1.8¡ÆF (outside)
pH Calibration   automatic, 1 or 2 point with 5 memorized buffer values
(pH 4.01, 6.86, 7.01, 9.18, 10.01)
mV Calibration   automatic, 2 point at 0, 350 mV or 0, 350, 1900 mV
Temperature Compensation   Automatic, -10 to 120¡ÆC (14 to 248¡ÆF)
pH Electrode   HI 1618D smart electrode with temperature sensor,
DIN connector and 1 m (3.3') cable (included)
PC Connection   HI 9200/9 IR interface,
connector the computer RS232 serial port
Logging Interval   selectable at 1, 2, 5, 10, 15 30, 60, 120 or 180 minutes
Printing Interval   selectable at 1, 2, 5, 10, 15 30, 60, 120 or 180 minutes
Power Supply   4 x 1.5V AA / approx. 350 hours of continuous use (with backlight OFF)
or 12 Vdc input
Environment   0 to 50¡ÆC (32 to 122¡ÆF); RH max 95%
Dimensions   220 x 87 x 75 mm (8.7 x 3.4 x 2.9")
Weight   550 g (1.2 lb.)

 HI 98230 /  HI 98240
¸ðµ¨¸í                                                 HI 98230                   HI 98240
ÃøÁ¤¹üÀ§:             pH                   -4.00 to 19.99               -4.00 to 19.99
                       mV(ISE)                       -                                 ¡¾400.0
                      mV(ORP)                      -                                 ¡¾2000
                          ¡ÆC                   -10.0 to 120.0                 -10.0 to 120.0
ÃÖ¼ÒÃøÁ¤´ÜÀ§:       pH                        0.01                                 0.01
                      mV(ISE)                         -                    0.1 (-400 to +400); 1
                      mV(ORP)                       -                    0.1 (-400 to +400); 1  
                           ¡ÆC                            0.1                             0.1
Á¤È®µµ:                 pH                          ¡¾0.01                           ¡¾0.01
(@20¡ÆC/68¡ÆF)   mV(ISE)                     -                    ¡¾0.5 (-400 to +400); ¡¾2  
                      mV(ORP)                        -                   ¡¾0.5(-400 to +400); ¡¾2  
                           ¡ÆC                    ¡¾0.5 (0 to 70); 1            ¡¾0.4 (0 to 70); 1
pH º¸Á¤:                                        Automatic 1 or 2 points with 5 memorized buffers
                                                           (pH 4.01, 6.86, 7.01, 9.18 or 10.01)
mV º¸Á¤:                                                -                  0, 350 mVµÎÆ÷ÀÎÆ® º¸Á¤
                                                                             ¶Ç´Â0, 350, 1900 mV ¼¼Æ÷ÀÎÆ®º¸Á¤
¿Âµµº¸Á¤:                                           Automatic from -10 to 120¡ÆC (14 to 248¡ÆF)
Àü±Ø:                                              HI 1618D(¿Âµµ¼¾¼­³»Àå,DIN,Àè,1 m (3.3¡¯) cable  
Computer Interface:                  HI 9200 (infrared interface) connected to serial RS 232 port
Printing/Logging Interval:          Selectable from 1, 2, 5, 10, 15, 30, 60, 120 and 180 minutes
Input Impedance:                                                         10©ö©÷ohm
Àü¿ø°ø±Þ:                                     4 batteries 1.5V AA/300 hours approx. continuous use
                                                                     or 12VDC adapter (incl.)
»ç¿ëȯ°æ:                                                32 to 122¡ÆF (0 to 50¡ÆC); RH 95%
±Ô°Ý:                                                         220x82x66 mm (8.6x3.2x2.6¡±)
¹«°Ô:                                                                   500 g (17.6 oz.)

Àü±¹ ¹è¼Û°¡´É (µµ¼­, »ê°£ ÀϺÎÁö¿ªÀº ¹è¼Ûºñ°¡ Ãß°¡µÉ ¼ö ÀÖ½À´Ï´Ù.)
ÀÔ±ÝÈ®ÀÎ ÈÄ 2~4ÀÏÀ̳»(°øÈÞÀÏ Á¦¿Ü)¿¡ ¹è¼ÛµÇ¸ç µµ¼­/»ê°£Áö¿ªÀÇ °æ¿ì 1~2ÀÏ Á¤µµ Ãß°¡ ¼Ò¿äµË´Ï´Ù.
¾÷ü¹è¼ÛÀÏ °æ¿ì °³º°Åû縦 ÅëÇØ ¹è¼ÛµÇ¸ç 1~2ÀÏ Ãß°¡ µÉ ¼ö ÀÖ½À´Ï´Ù.
»óÇ°±¸¸Å¾×ÀÌ 10¸¸¿øÀÌ»óÀÎ °æ¿ì ¹è¼Û·á°¡ ¹«·áÀ̸ç 10¸¸¿ø¹Ì¸¸ÀÎ °æ¿ì¿¡´Â 5,000¿øÀÌ ºÎ°úµË´Ï´Ù(b2b°Å·¡´Â º°µµ ¹è¼Ûºñ Ã¥Á¤).
¹«·á¹è¼ÛÁ¦Ç°Àº ´ÜÇ°¿¡ ÇÑÇØ ¹«·á¹è¼ÛµÇ¸ç ±âŸ Á¦Ç°°ú µ¿½Ã ±¸¸Å½Ã ¹è¼Ûºñ Ã¥Á¤±âÁØ¿¡¼­ Á¦¿ÜµË´Ï´Ù.
´ëÇÑ°úÇÐ ¼îÇθô ¹è¼ÛÀÏ °æ¿ì02-967-5978 À» ÅëÇØ ¹è¼ÛµÇ¸ç ¹è¼ÛÇöȲÀº ÁÖ¹®/¹è¼ÛÁ¶È¸¿¡¼­ È®ÀÎÇÏ½Ç ¼ö ÀÖ½À´Ï´Ù.
±³È¯ ¹× ¹ÝÇ°ÀÌ °¡´ÉÇÑ°æ¿ì
°ø±Þ¹ÞÀ¸½Ã´Â »óÇ°ÀÇ ³»¿ëÀÌ Ç¥½Ã, ±¤°í ³»¿ë°ú ´Ù¸£°Å³ª »óÇ°ÀÌ ÆļÕ/¼Õ»óµÇ¾ú°Å³ª ºÒ·® Á¦Ç°ÀÏ °æ¿ì¿¡´Â °ø±Þ¹Þ´Â ³¯·ÎºÎÅÍ
7ÀÏ À̳»¿¡ º»»ç¿Í »ó´ãÈÄ ±³È¯ ¹× ¹ÝÇ°ÀÌ °¡´ÉÇÏ¸ç ¼ö°Å ¹× Àç¹ß¼Û ºñ¿ëÀº º»»ç°¡ ºÎ´ãÇÕ´Ï´Ù.
´Ü °í°´´ÔÀÇ ´Ü¼ø º¯½É ¶Ç´Â »ö»ó, Å©±â(ÀÇ·ù,½Å¹ß)º¯°æÀ¸·Î ÀÎÇÑ ±³È¯ ¹ÝÇ°Àº 7ÀÏ À̳»¿¡ ±³È¯/¹ÝÇ°°¡´ÉÇÏ¸ç ¼ö°Å ¹× Àç¹ß¼Û
ºñ¿ëÀ» °í°´´Ô²²¼­ ºÎ´ãÇÏ¼Å¾ß ÇÕ´Ï´Ù.

¹Ýµå½Ã 02-967-5978 À» ÅëÇØ ¹ÝÇ°ÇÏ¿©¾ß ÇÏ¸ç ±âŸ Åùè»ç¸¦ ÀÌ¿ëÇÒ °æ¿ì ¼öÃë°ÅºÎ µÉ ¼ö ÀÖ½À´Ï´Ù.


±³È¯ ¹× ¹ÝÇ°ÀÌ ºÒ°¡´ÉÇÑ°æ¿ì
°í°´´ÔÀÇ ´Ü¼ø º¯½É ¶Ç´Â »ö»ó, Å©±â µîÀÇ º¯°æÀ» À§ÇÑ ¹ÝÇ° ¹× ±³È¯½Ã¿¡´Â »óÇ°ÀÇ ÅÂ±×¿Í Æ÷Àå»óÅÂ(¹Ú½º)¸¦ º¸Á¸ÇÏ¼Å¾ß ÇÕ´Ï´Ù.
Æ÷ÀåÀ» °³ºÀÇÏ¿© »ç¿ëÇÑ ÈçÀûÀÌ Àְųª Æ÷ÀåÀÌ ÈÑ¼ÕµÇ¾î »óÇ° °¡Ä¡°¡ ÇöÀúÈ÷ »ó½ÇµÈ °æ¿ì¿¡´Â ±³È¯ ¹× ȯºÒÀÌ ºÒ°¡´ÉÇÕ´Ï´Ù. 
(¿¹: ¹ÝÇ°½Ã ¿ø¹Ú½º¿¡ ÁÖ¼Ò±âÀÔ, ¹Ú½º¿ëÅ×ÀÌÇÁ»ç¿ë, µî ¹Ýµå½Ã ´ç»ç¿¡¼­ º¸³»µå¸° 2Áß¹Ú½º·Î º¸³»ÁּžßÇÕ´Ï´Ù.)

ȯºÒ ¹× AS
ȯºÒÀº ¹Ý¼Û È®ÀÎ ÈÄ °¡´ÉÇÏ¸ç ¹Ýµå½Ã °í°´¸¸Á·¼¾ÅÍ¿Í »ó´ã ÈÄ ¹Ý¼ÛÇÏ¿©¾ß Çϸç Àû¸³±ÝÀ¸·Îµµ ȯºÒ ¹ÞÀ¸½Ç ¼ö ÀÖ½À´Ï´Ù.
»óÇ° »ç¿ë¹æ¹ý ¹× »óÇ°¿¡ ´ëÇÑ ¹®ÀÇ´Â °í°´Çູ¼¾ÅÍ(02-967-5978), q&a °Ô½ÃÆÇ, 1:1¹®ÀÇ °Ô½ÃÆÇ µî¿¡ ¹®ÀÇÇϼ¼¿ä
»óÇ° »ç¿ëÁß ¹ß»ýÇÏ´Â a/s´Â ÇØ´ç ¼öÀÔ ¹× °ø±Þ¾÷ü¿Í Á÷Á¢ »ó´ãÇÏ¼Å¾ß ÇÕ´Ï´Ù.

(0) À̸§ Á¶È¸ µî·ÏÀÏ ´äº¯
 »óÇ°¿¡ ´ëÇÑ ¹®ÀDZÛÀÌ ¾ø½À´Ï´Ù

(0) À̸§ Á¶È¸ µî·ÏÀÏ
 »óÇ°¿¡ ´ëÇÑ Æò°¡±ÛÀÌ ¾ø½À´Ï´Ù



»ç¾÷ÀÚ µî·ÏÁõ &..
ȨÆäÀÌÁö ¾÷±×·¹..
¿Â¶óÀÎ °ßÀû¹× ..
Á¾ÇÕ Ä«´Þ·Î±× ..
A/S Á¢¼ö¾È³»
°ßÀû ¿äû
°ßÀû¿äûÇÕ´Ï´Ù.
°ßÀû ºÎŹµå¸³´Ï´Ù.
°ßÀûºÎŹµå¸³´Ï´Ù. ^^
°ßÀû ºÎŹ µå¸³´Ï´Ù.
UP351 Program Controller ..
Yokogawa CW-240 Çѱ۸޴º..
¿Âµµ & ½Àµµ ´ÜÀ§ °ü·ÃÀÚ·á
°¡½º³óµµ ¿ë¾îÇؼ³
RE:°¡½º³óµµ ¿ë¾îÇؼ³
±â±â A/S ¼ö¸® ¹®ÀÇ
°Ô½ÃÆÇÀÇ ¼º°Ý°ú ¸ÂÁö ¾Ê´õ..
°è´Ü ¿î¹ÝÂ÷ -600kg
ÇÇÆ꺸ÀÌ ¹®ÀÇÇÕ´Ï´Ù.
¸¶Á¶´Ï¾Æ°ü ¹®ÀÇ
ȸ»ç¼Ò°³ ¤Ó °³ÀÎÁ¤º¸º¸È£Á¤Ã¥ ¤Ó ÀÌ¿ë¾à°ü ¤Ó °í°´¼¾ÅÍ
¼­¿ï : ¼­¿ï Á¾·Î±¸ Àͼ±µ¿ 55¹øÁö Çö´ë¶ß·¹ºñ¾Ó 422È£ (Hyundai Tres Bien@422 Iksun-dong 55 Jongno-Gu Seoul, Korea) (110-340)
Tel : 02-967-5978 (010-3768-8228)   Fax : 02-967-5979   E-mail : dhslkorea@naver.com
»ç¾÷ÀÚµî·Ï¹øÈ£ : 209-04-47629 ´ëÇ¥ : ±è¹Î¿Á   ½Ã°èÅë½ÅÆǸž÷½Å°í¹øÈ£ : Á¾·Î 01-3204
Copyrights ¨Ï ´ëÇÑ°úÇÐ All replica reserved.
Table 'dhslkorea2.kimson_referer' doesn't exist