¡áƯ ¡ (Features ) * The HI 9024 is a microprocessor-based pH meter housed in a rugged waterproof casing that can measure pH and temperature. * The Auto-Instruction feature guides the user step-by-step through the calibration process with graphic symbols. * The automatic calibration procedure is simple and quick and can be performed at 1 or 2 points selected from 5 memorized buffers: pH 4.01, 6.86, 7.01, 9.18 and 10.01. A stability indicator assures a correct calibration. * It also feature an automatic shut-off to save battery life. * The HI 9025 is a microprocessor-based pH meter that is housed in a rugged waterproof casings that can measures pH/ORP and temperature. * The Auto-Instruction feature guides the user step-by-step through the calibration process with graphic symbols. * The automatic calibration procedure is simple and quick and can be performed at 1 or 2 points selected from 5 memorized buffers: pH 4.01, 6.86, 7.01, 9.18 and 10.01. A stability indicator assures a correct calibration. * This meter also features an automatic shut-off to save battery life.
¡á ±Ô°Ý(Specifications)
±¸ºÐ
pH
HI 9024
HI 9025
Range
pH
0.00 to 14.00 pH
0.00 to 14.00 pH
Range
mV
------
¡¾399.9 mV; ¡¾1999 mV
Range
Temperature
0.0 to 100.0¡ÆC / 32 to 212.0¡ÆF
0.0 to 100.0¡ÆC / 32 to 212.0¡ÆF
Resolution
pH
0.01 pH
0.01 pH
Resolution
Temperature
0.1¡ÆC / 0.1¡ÆF
0.1¡ÆC / 0.1¡ÆF
Resolution
mV
------
0.1 mV; 1 mV
Accuracy
pH
¡¾0.01 pH
¡¾0.01 pH
Accuracy
mV
------
¡¾0.2 mV; ¡¾1 mV
Accuracy
Temperature
¡¾0.4¡ÆC; ¡¾0.8¡ÆF
¡¾0.4¡ÆC; ¡¾0.8¡ÆF
pH Calibration
automatic, 1 or 2 point with 5 memorized buffer values (pH 4.01, 6.86, 7.01, 9.18, 10.01); offset calibration: ¡¾1 pH; Slope Calibration: 70 to 108%
automatic, 1 or 2 point with 5 memorized buffer values (pH 4.01, 6.86, 7.01, 9.18, 10.01); offset calibration: ¡¾1 pH; Slope Calibration: 70 to 108%
Temperature Compensation
automatic or manual, -5 to 105¡ÆC (23 to 221¡ÆF)
automatic or manual, -5 to 105¡ÆC (23 to 221¡ÆF)
pH Electrode
HI 1230B double junction, PEI (PolyEther-Imide) body, gel filled, BNC connector and 1 m (3.3') cable (included)
HI 1230B double junction, PEI (PolyEther-Imide) body, gel filled, BNC connector and 1 m (3.3') cable (included)
Temperature Probe
HI 7669/2W with 1 m (3.3') cable (included)
HI 7669/2W with 1 m (3.3') cable (included)
Input Impedance
1012 Ohm
1012 Ohm
Battery Type / Life
4 x 1.5V AA / approx. 500 hours of continuous use (with backlight OFF): auto-off after 20 minutes of non-use (can be disabled)
4 x 1.5V AA / approx. 500 hours of continuous use (with backlight OFF): auto-off after 20 minutes of non-use (can be disabled)