·Î±×ÀÎ ¤Ó ȸ¿ø°¡ÀÔ ¤Ó Àå¹Ù±¸´Ï ¤Ó ÁÖ¹®/¹è¼ÛÁ¶È¸ ¤Ó ã¾Æ¿À½Ã´Â±æ ¤Ó Agency Shop
¼¼ÀÏ»óÇ° |  Á¦Ç°¼Ò°³ |  ¿Â¶óÀΰßÀû¼­ |  i-Shop |  °ü·Ã»çÀÌÆ® |  Manual |  ±â¼úÁ¤º¸ |  °í°´¼¾ÅÍ |  ¹°¹°±³È¯
Keyword or Catalog No (»óÇ°¸í.¸ðµ¨¸í.Á¦Á¶»ç¸í)    
¾ÆÀ̵ð
ºñ¹Ð¹øÈ£
¾ÆÀ̵ð ÀúÀå
¤¡. °ü·Ã»óÇ°º¸±â ¨¿
¤¤. °ü·Ã»óÇ°º¸±â ¨À
¤§. °ü·Ã»óÇ°º¸±â ¨Á
¤©. °ü·Ã»óÇ°º¸±â ¨Â
¤±. °ü·Ã»óÇ°º¸±â ¨Ã
¤². °ü·Ã»óÇ°º¸±â ¨Ä
¤µ. °ü·Ã»óÇ°º¸±â ¨Å
¤·. °ü·Ã»óÇ°º¸±â ¨Æ
¤¸. °ü·Ã»óÇ°º¸±â ¨Ç
¤º. °ü·Ã»óÇ°º¸±â ¨È
¤». °ü·Ã»óÇ°º¸±â ¨É
¤¼. °ü·Ã»óÇ°º¸±â ¨Ê
¤½. °ü·Ã»óÇ°º¸±â ¨Ë
¤¾. °ü·Ã»óÇ°º¸±â ¨Ì
* °úÇб³Àç (ÃÊ.Áß.°í)
* ±ÝÇü¼³°è.»çÃ⼺Çü
* ÁÖ¹®Á¦ÀÛÇ° (À¯¸®.Å×ÇÁ·Ð.±Ý¼Ó)
* ½Ã¾à. Àç·á.ÇÕ±Ý.Ÿ°Ù.¿þÀÌÆÛ
·¹µåºí·° Å×½ºÆ®¿ë  
±â¾÷ÀºÇà 086-023289-04-011
¿ì¸®ÀºÇà 048-401225-13-001
¿¹±ÝÁÖ : ±è¹Î¿Á
Alphabet Index
A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z

"Dewyer" A3000 Series Photohelic Pressure Switch/gages 3-In-One Indicating Gage, LO-Limit abd Hi-Limit Control
Á¤»ó°¡ : 0¿ø
ÆǸŰ¡ :  VAT Æ÷ÇÔ°¡
Àû¸³±Ý : 0¿ø
¹è¼Ûºñ : ÀϹÝ(°áÁ¦ÃѾ׿¡ µû¶ó¼­ º¯µ¿)
ÁÖ¹®¼ö·® :
°³

¡á Á¦Ç°ÄÚµå(CAT No) / °¡°ÝÇ¥(Price)
»óÇ°ÄÚµå Description ´ÜÀ§/°¹¼ö ÆǸŰ¡ VAT ÁÖ¹®Çϱâ

¡á Á¦Ç°ÄÚµå(CAT No) / °¡°ÝÇ¥(Price)

CAT No.

Description

´ÜÀ§/°¹¼ö

Price[VATº°µµ]


»óÇ°¹®ÀÇ

¡Ø Note! Ç¥½Ã°¡°ÝÀº ȯÀ² ¹× ¿øÀÚÀç º¯È­·Î º¯µ¿µÉ ¼ö ÀÖÀ¸¸ç ±ÇÀå ¼ÒºñÀÚ °¡°ÝÀÓ ( VAT º°µµ)¢Î 02)967-5978
±Ô°Ý¿Ü ÁÖ¹®Á¦ÀÛ ¹× °¡°Ý ³»°í °¡ ÇÊ¿ä·Î ÇϽŠºÐÀº º°µµ·Î °ßÀû¿äû or ÀüÈ­¹®ÀÇ ¹Ù¶ø´Ï´Ù.
FAX:02)967-5979
¡ØÀÎÅÍ³Ý ÁÖ¹®ÀÌ ÇÊ¿äÇϽŠºÐÀº ÀüÈ­Áֽøé ÇöÀç°¡°Ý µî·Ï ¼öÁ¤ ÈÄ ¿Â¶óÀÎ ÁÖ¹® °¡´ÉÇÕ´Ï´Ù

¡á ¿ëµµ(Applications)

¡á
Ư ¡ (Features )
Photohelic¢ç Switch/Gages function as versatile, highly repeatable pressure switches combined with a precise pressure gage employing the time-proven Magnehelic¢ç design. The Photohelic¢ç measures and controls positive, negative or differential pressures of air and compatible gases.
Standard models are rated to 25 psig (1.7 bar) with options to 35 (2.4) or 80 (5.5 bar) psig. Single pressure 36000S models measure to 6000 psig (413 bar) with a 9000 psig (620 bar) rating. Two phototransistor actuated, DPDT relays are included for low/high limit control. Easy to adjust setpoint indicators are controlled by knobs located on the gage face. Individual setpoint deadband is one pointer width — less than 1% of full scale. Setpoints can be interlocked to provide variable deadband — ideal for control of fans, dampers, etc. Gage reading is continuous and unaffected by switch operation, even during loss of electrical power. Choose from full scale pressure ranges from a low 0-.25" (0-6 mm) w.c. up
to 30 psi (21 bar); single positive pressure to 6000 psig (413 bar).
PHOTOHELIC SENSING — HOW IT WORKS
In typical applications, these Dwyer switch/gages control between high and low pressure set points. When pressure changes, reaching either set point pressure, the infrared light to the limiting phototransistor is cut off by the helix-driven light shutter. The resulting phototransistor signal is electronically amplified to actuate its DPDT slave relay and switching occurs. Dead band between make and break is 1% of full scale or less — just enough to assure positive, chatter-free operation.
RELAY-TRANSFORMER FEATURES
A plastic housing protects all electronic components. Solid-state and integrated circuit electronics are on glass-epoxy printed circuit boards and self-extinguishing terminal boards (for the Series A3000 only).
APPLICATIONS — PHOTOHELIC SWITCH/GAGES
In both series of pressure switch/gages, you get the convenience of a visual indication plus high-low limit switching. For both OEM and inplant applications, the Photohelic¢ç switch/gage is used to control pressures in air conditioning systems, clean rooms, fluidic and pneumatic control systems, materials handling equipment, alarm or control fume exhaust systems, control pressure in air structures, and monitor respiratory and blood pressures.

¡á ±Ô°Ý(Specifications)
GAGE SPECIFICATIONS
Service : Air and non-combustible, compatible gases.
Wetted Materials : Consult factory.
Accuracy : ¡¾2% of full scale at 70¡ÆF (21.1¡ÆC). ¡¾3% on -0 and ¡¾4% on -00 models.

Pressure Limits : -20" Hg. to 25 psig (-0.677 to 1.72 bar). MP option; 35 psig (2.41 bar), HP option; 80 psig (5.52 bar). 36003S – 36010S; 150 psig (10.34 bar). 36020S and higher; 1.2 x full scale pressure.

Temperature Limits : 20 to 120¡ÆF.

(-6.67 to 48.9¡ÆC) Low temperature option available.

Process Connections : 1/8¢© female NPT.

Size : 4¢© (101.6 mm) dial face, 5¢© (127 mm) O.D. x 8-1/4¢© (209.55 mm).

Weight : 4 lb (1.81 kg).

 

SWITCH SPECIFICATIONS

Switch Type : Each setpoint has 2 Form C relays (DPDT).

Repeatability : ¡¾1% of full scale.

Electrical Rating : 10A @ 28 VDC, 10A @ 120, 240 VAC.

Electrical Connections : Screw terminals.

Power Requirements : 120 VAC, 50/60 Hz; 240 VAC & 24 VAC Power optional.

Mounting Orientation : Diaphragm in vertical position. Consult factory for other position orientations.

Set Point Adjustment : Adjustable knobs on face.

Agency Approvals : UL, CSA, CE.

 

¢º STANDARD MODEL

Two phototransistor-actuated circuits and two DPDT relays permit both high and low alarms or limit controls. Relays are de-energized when gage pointer is to the left of respective set points; relays are energized as pointer passes to the right of set points. Loss of electrical power or loss of pressure provide ¡°fail safe¡± protection.

 

¢º OPTIONS

Single contact, right set point, for actuation on increasing or decreasing pressure. OEM Model, less relay and transformer components and housing but including infrared diodes and phototransistor(s), light shutter and set pointer(s). For single or double contact. Remote-Mounted Relay, relay pack may be mounted remotely from gage. Standard length is 5 ft. For other lengths, specify cable length required. Tamper-proof knobs, low temperature option, special scales, voltages and other features and modifications are available.

Special Housings available include Weatherproof (NEMA 4) and Explosion-proof (NEMA 7 CD, 9 EFG; NEC Class I, DIV. 1 & 2, Groups C, D, Class II, Div. 1 & 2, Groups E, F, G, Class III. Contact Customer Service for detailed dimension drawings.

HIGH AND LOW LATCHING CIRCUITS

Dwyer Photohelic¢ç switch/gages can be wired for high - latching, low-latching or combination high-low latching circuits. That is, the equipment will hold in these respective positions once activated and until manually reset. This can be particularly useful for alarm and signal applications where control is accomplished by another Photohelic¢ç switch/gage or other means. Complete wiring and operational instructions are included. Where manual reset is required a dry circuit push button such as Dwyer Part A-601 should be used

Àü±¹ ¹è¼Û°¡´É (µµ¼­, »ê°£ ÀϺÎÁö¿ªÀº ¹è¼Ûºñ°¡ Ãß°¡µÉ ¼ö ÀÖ½À´Ï´Ù.)
ÀÔ±ÝÈ®ÀÎ ÈÄ 2~4ÀÏÀ̳»(°øÈÞÀÏ Á¦¿Ü)¿¡ ¹è¼ÛµÇ¸ç µµ¼­/»ê°£Áö¿ªÀÇ °æ¿ì 1~2ÀÏ Á¤µµ Ãß°¡ ¼Ò¿äµË´Ï´Ù.
¾÷ü¹è¼ÛÀÏ °æ¿ì °³º°Åû縦 ÅëÇØ ¹è¼ÛµÇ¸ç 1~2ÀÏ Ãß°¡ µÉ ¼ö ÀÖ½À´Ï´Ù.
»óÇ°±¸¸Å¾×ÀÌ 10¸¸¿øÀÌ»óÀÎ °æ¿ì ¹è¼Û·á°¡ ¹«·áÀ̸ç 10¸¸¿ø¹Ì¸¸ÀÎ °æ¿ì¿¡´Â 5,000¿øÀÌ ºÎ°úµË´Ï´Ù(b2b°Å·¡´Â º°µµ ¹è¼Ûºñ Ã¥Á¤).
¹«·á¹è¼ÛÁ¦Ç°Àº ´ÜÇ°¿¡ ÇÑÇØ ¹«·á¹è¼ÛµÇ¸ç ±âŸ Á¦Ç°°ú µ¿½Ã ±¸¸Å½Ã ¹è¼Ûºñ Ã¥Á¤±âÁØ¿¡¼­ Á¦¿ÜµË´Ï´Ù.
´ëÇÑ°úÇÐ ¼îÇθô ¹è¼ÛÀÏ °æ¿ì02-967-5978 À» ÅëÇØ ¹è¼ÛµÇ¸ç ¹è¼ÛÇöȲÀº ÁÖ¹®/¹è¼ÛÁ¶È¸¿¡¼­ È®ÀÎÇÏ½Ç ¼ö ÀÖ½À´Ï´Ù.
±³È¯ ¹× ¹ÝÇ°ÀÌ °¡´ÉÇÑ°æ¿ì
°ø±Þ¹ÞÀ¸½Ã´Â »óÇ°ÀÇ ³»¿ëÀÌ Ç¥½Ã, ±¤°í ³»¿ë°ú ´Ù¸£°Å³ª »óÇ°ÀÌ ÆļÕ/¼Õ»óµÇ¾ú°Å³ª ºÒ·® Á¦Ç°ÀÏ °æ¿ì¿¡´Â °ø±Þ¹Þ´Â ³¯·ÎºÎÅÍ
7ÀÏ À̳»¿¡ º»»ç¿Í »ó´ãÈÄ ±³È¯ ¹× ¹ÝÇ°ÀÌ °¡´ÉÇÏ¸ç ¼ö°Å ¹× Àç¹ß¼Û ºñ¿ëÀº º»»ç°¡ ºÎ´ãÇÕ´Ï´Ù.
´Ü °í°´´ÔÀÇ ´Ü¼ø º¯½É ¶Ç´Â »ö»ó, Å©±â(ÀÇ·ù,½Å¹ß)º¯°æÀ¸·Î ÀÎÇÑ ±³È¯ ¹ÝÇ°Àº 7ÀÏ À̳»¿¡ ±³È¯/¹ÝÇ°°¡´ÉÇÏ¸ç ¼ö°Å ¹× Àç¹ß¼Û
ºñ¿ëÀ» °í°´´Ô²²¼­ ºÎ´ãÇÏ¼Å¾ß ÇÕ´Ï´Ù.

¹Ýµå½Ã 02-967-5978 À» ÅëÇØ ¹ÝÇ°ÇÏ¿©¾ß ÇÏ¸ç ±âŸ Åùè»ç¸¦ ÀÌ¿ëÇÒ °æ¿ì ¼öÃë°ÅºÎ µÉ ¼ö ÀÖ½À´Ï´Ù.


±³È¯ ¹× ¹ÝÇ°ÀÌ ºÒ°¡´ÉÇÑ°æ¿ì
°í°´´ÔÀÇ ´Ü¼ø º¯½É ¶Ç´Â »ö»ó, Å©±â µîÀÇ º¯°æÀ» À§ÇÑ ¹ÝÇ° ¹× ±³È¯½Ã¿¡´Â »óÇ°ÀÇ ÅÂ±×¿Í Æ÷Àå»óÅÂ(¹Ú½º)¸¦ º¸Á¸ÇÏ¼Å¾ß ÇÕ´Ï´Ù.
Æ÷ÀåÀ» °³ºÀÇÏ¿© »ç¿ëÇÑ ÈçÀûÀÌ Àְųª Æ÷ÀåÀÌ ÈÑ¼ÕµÇ¾î »óÇ° °¡Ä¡°¡ ÇöÀúÈ÷ »ó½ÇµÈ °æ¿ì¿¡´Â ±³È¯ ¹× ȯºÒÀÌ ºÒ°¡´ÉÇÕ´Ï´Ù. 
(¿¹: ¹ÝÇ°½Ã ¿ø¹Ú½º¿¡ ÁÖ¼Ò±âÀÔ, ¹Ú½º¿ëÅ×ÀÌÇÁ»ç¿ë, µî ¹Ýµå½Ã ´ç»ç¿¡¼­ º¸³»µå¸° 2Áß¹Ú½º·Î º¸³»ÁּžßÇÕ´Ï´Ù.)

ȯºÒ ¹× AS
ȯºÒÀº ¹Ý¼Û È®ÀÎ ÈÄ °¡´ÉÇÏ¸ç ¹Ýµå½Ã °í°´¸¸Á·¼¾ÅÍ¿Í »ó´ã ÈÄ ¹Ý¼ÛÇÏ¿©¾ß Çϸç Àû¸³±ÝÀ¸·Îµµ ȯºÒ ¹ÞÀ¸½Ç ¼ö ÀÖ½À´Ï´Ù.
»óÇ° »ç¿ë¹æ¹ý ¹× »óÇ°¿¡ ´ëÇÑ ¹®ÀÇ´Â °í°´Çູ¼¾ÅÍ(02-967-5978), q&a °Ô½ÃÆÇ, 1:1¹®ÀÇ °Ô½ÃÆÇ µî¿¡ ¹®ÀÇÇϼ¼¿ä
»óÇ° »ç¿ëÁß ¹ß»ýÇÏ´Â a/s´Â ÇØ´ç ¼öÀÔ ¹× °ø±Þ¾÷ü¿Í Á÷Á¢ »ó´ãÇÏ¼Å¾ß ÇÕ´Ï´Ù.

(0) À̸§ Á¶È¸ µî·ÏÀÏ ´äº¯
 »óÇ°¿¡ ´ëÇÑ ¹®ÀDZÛÀÌ ¾ø½À´Ï´Ù

(0) À̸§ Á¶È¸ µî·ÏÀÏ
 »óÇ°¿¡ ´ëÇÑ Æò°¡±ÛÀÌ ¾ø½À´Ï´Ù



»ç¾÷ÀÚ µî·ÏÁõ &..
ȨÆäÀÌÁö ¾÷±×·¹..
¿Â¶óÀÎ °ßÀû¹× ..
Á¾ÇÕ Ä«´Þ·Î±× ..
A/S Á¢¼ö¾È³»
°ßÀû ¿äû
°ßÀû¿äûÇÕ´Ï´Ù.
°ßÀû ºÎŹµå¸³´Ï´Ù.
°ßÀûºÎŹµå¸³´Ï´Ù. ^^
°ßÀû ºÎŹ µå¸³´Ï´Ù.
UP351 Program Controller ..
Yokogawa CW-240 Çѱ۸޴º..
¿Âµµ & ½Àµµ ´ÜÀ§ °ü·ÃÀÚ·á
°¡½º³óµµ ¿ë¾îÇؼ³
RE:°¡½º³óµµ ¿ë¾îÇؼ³
±â±â A/S ¼ö¸® ¹®ÀÇ
°Ô½ÃÆÇÀÇ ¼º°Ý°ú ¸ÂÁö ¾Ê´õ..
°è´Ü ¿î¹ÝÂ÷ -600kg
ÇÇÆ꺸ÀÌ ¹®ÀÇÇÕ´Ï´Ù.
¸¶Á¶´Ï¾Æ°ü ¹®ÀÇ
ȸ»ç¼Ò°³ ¤Ó °³ÀÎÁ¤º¸º¸È£Á¤Ã¥ ¤Ó ÀÌ¿ë¾à°ü ¤Ó °í°´¼¾ÅÍ
¼­¿ï : ¼­¿ï Á¾·Î±¸ Àͼ±µ¿ 55¹øÁö Çö´ë¶ß·¹ºñ¾Ó 422È£ (Hyundai Tres Bien@422 Iksun-dong 55 Jongno-Gu Seoul, Korea) (110-340)
Tel : 02-967-5978 (010-3768-8228)   Fax : 02-967-5979   E-mail : dhslkorea@naver.com
»ç¾÷ÀÚµî·Ï¹øÈ£ : 209-04-47629 ´ëÇ¥ : ±è¹Î¿Á   ½Ã°èÅë½ÅÆǸž÷½Å°í¹øÈ£ : Á¾·Î 01-3204
Copyrights ¨Ï ´ëÇÑ°úÇÐ All replica reserved.
Table 'dhslkorea2.kimson_referer' doesn't exist